is the new external defibrillator that is so small and light it fits in every coat pocket and every doctor's bag, and still meets all requirements of a modern AED (Automatic External Defibrillator). has an ECG display

15V d.c. 2.8Ah Battery ,Capacity: 100 discharges at 200 Joules or 120 discharges at 150 Joules,Shelf Life: 5 years

Micro SD card for data record

Defi 6 features

  • 2-in-1 Design

    AED and ECG Monitor

  • Clear Visibility

    3.5 inch TFT Display

  • SD Socket

    Data storage feature(ecg, audio, event)

  • Multi Language

    English.Spanish.Chinese.Turkish 

  • Self Test

    Daily,Weekly,Monthly Self test

  • Data transfer

    Infrared data transmission

Output: Biphasic Truncated exponential
Energy Sequence(adult ): 150/150/200(Default) .150/200/200 . 200/200/200
Energy Sequence(Pediatric): 50/70/85(Default) . 70/70/85 . 70/85/85 . 85/85/85
Charge Time: Less than 10 sec. to 200J
Analysis Time: 9 sec.
Less than 30 seconds is the maximum time from the initiation of rhythm analysis to readiness for maximum Energy discharge after 15 shocks.
Less than 35seconds is the maximum time from initially switching power on to readiness for maximum Energy discharge after 15 shocks..
Audible Prompts 19 audible prompts
Self-test battery, main processor, memory and program, ECG acquisition system, and defibrillator.
Visual Prompts LED/LCD
Controls: six buttons - On/Off, Shock, and 4 software-configurable buttons
Output Energy Accuracy: ±15% into any impedance from 25 to 175Ω
Non-rechargeable  Battery :   15V d.c. 2.8Ah , Capacity 100 discharges at 200 Joules or 120 discharges at 150 Joules

 

A: Defibrillation counter
B: SD card 
C: Pressure sensor icon
E: Date and time
F: Battery
H: Pressure sensor intensity bar
 I : User mode
J: System status
K: Pad status
L: Filter status
M: Ecg waveform area

 

Phisycal Specifications

Dimensions: 225 x 200 x 85mm
Weight: 2.0 kg
Operating Temperature: 0℃ to 40℃
Operating Humidity: Relative humidity between 30% and 95% (non-condensing)
Altitude: -300 to 15,000 ft( -91m to 4573m)
Pressure: 102.4kPa~57.2kPa(768mmHg~429mmHg)
Storage Temperature
(without battery): -20℃ to 55℃
Storage Humidity
(without battery): Up to 93% (non-condensing)
Particle and Water Ingress: IP24
 

Defi 6 Options and Accessories

LiMnO2 Battery

Working power: 15V , 2.6Ah
 
Normal working condition:
Working temperature:5~40C
Relative temperature:=80%
Atmospheric pressure:86kpa~106kpa
The size:
The weight:
 
 
Attention:
Do not dispose of in fire or put into water
Do not disassemble or short circuit
Do not use in high temprature or near heat sourse
 

AED PAD

MDC-W4

AED Cabinet W4
MDC-W4
 
Material: Metal+ Plastic glass
Size: 36x40x20CM
Color: any color available
Sound & Light Alarm
Video Screen ( 200mmx110mm)
 
Carton size: 435*395*235 mm 
Gross weight: 8.5kgs 

MDC-W2

AED Cabinet W2
MDC-W2
 
Material: Metal+ Plastic glass
Size: 48x38x24CM
Color: any color available
Sound alarm
Adjustable Heating System
 
Carton size: 510x410x260 mm
Gross weight: 7.5kgs

MDC-W3

AED Cabinet W3
MDC-W3
 
Material: Metal+ Plastic glass
Size: 48x38x24CM
Color: any color available
Sound alarm
Adjustable Heating System
 
Carton size: 510x410x260 mm
Gross weight: 7.5kgs

MDC-W1

AED Cabinet W1
MDC-W1
 
Material: Metal+ Plastic glass
Size: 38x42x15.5cm
Color: any color available
Sound alarm
 
 
Carton size: 440x400x240 mm
Gross weight: 7.0kgs

IR-210U USB to IrDA

infra Red for ECG Data transfer

Enclosure

  • Dimensions: 4.75 cm W x 6.35 cm L x 1.9 cm H
  • Unit Weight: 113.4 grams (including 10' cable)

Display

  • Red LED to indicate response traffic

Power and Power Management

  • Powered by USB port

Range

  • Approximately 27.5 m
  • Range can be increased by utilizing multiple receivers.

Capacity

  • 80 ResponseCard keypads per (1) IR Receiver

ECG cable

3 Lead ECG cable ecg cable for aed
3 Lead ECG cable
  • LiMnO2 Battery

  • AED PAD

  • MDC-W4

    AED Cabinet W4
  • MDC-W2

    AED Cabinet W2
  • MDC-W3

    AED Cabinet W3
  • MDC-W1

    AED Cabinet W1
  • IR-210U USB to IrDA

    infra Red for ECG Data transfer
  • ECG cable

    3 Lead ECG cable

Frequently asked questions

  • does Defi6 AED have a metronome

    Defi6 AED defibrillator have metronome function

  • Is the AED safe to shock on wet

     No, it will effect the result of shock 
    If the person is in water, remove him or her from the water before 
         defibrillation.
    A shock delivered in water could harm responders or bystanders. 
    Once you have removed the person from the water, be sure there 
         are no puddles of water around you, the person or the AED. 
    Remove wet clothing to place the pads properly, if necessary. 
    Dry the person's chest and attach the AED pads.

  • Is there Any software required

    Yes, there is a software to view on PC after transfer the data (optional)

Didn’t find the answer you were looking for? Find a distributor in your country